Page 2 of 2 FirstFirst 12
Results 21 to 22 of 22

Thread: 5.56 vs .223 question

  1. #21
    Senior Member
    Join Date
    Feb 2010
    Location
    Eastern Oregon
    Posts
    228

    Default

    Quote Originally Posted by Ned Christiansen View Post
    This is from a contact at ATK / Federal Cartridge. Italics are mine:

    00000000000000000000000000000000000000000000000000 00

    5.56 vs/ .223
    To ensure operational reliability, the 5.56 round is designed to operate at significantly higher pressures, namely just short of 59,000 psi (case mouth meaured) which equates to almost 62,000psi when measured via conformal transducer (as done by SAAMI).

    The SAAMI max set forth for the 223 is 55,000psi (conformal transducer).

    To facilitate operating under these higher pressures, a 5.56 cartridge case possesses a stronger web design (thicker case walls towards the head), reducing internal powder volume, an important consideration for reloaders.
    The remaining differences are found in the chambering of the weapon. A 5.56 chambered weapon differs from a .223 in the throat and freebore. A 5.56 throat is approx. 30 thousandths of an inch longer and 3 thousandths of an inch larger in diameter than a 223 chamber. In addition, the throat or “start point” of the rifling, the taper with which the lands begin, is at a lesser angle, more gradual in a 5.56 than in the .223.

    These rather small, but very important differences, allow peak pressures to drop adequately before the bullet engages the rifling and also allow for more build-up of fouling and shooting residue without impeding function.

    What does all this mean? In short, you can safely fire all 5.56 AND .223 ammunition in a gun properly chambered for 5.56. You MUST NOT fire 5.56 ammunition in a 223 rifle. As case in point, I fired XM193 5.56 ammunition in a .223 test barrel with average pressures (conformal transducer) of 72,550 psi, and peak pressure registered at 76,250 psi. Continued shooting of 5.56 ammunition in guns not chambered for 5.56 will show many warning signs of over-pressure, such as flattening of primers, smearing of the head stamp, dropped primers, blown primers and pre-mature wear on extractors and bolts.
    00000000000000000000000000000000000000000000000000 000000
    Well done

  2. #22
    Senior Member
    Join Date
    May 2010
    Location
    N.W Oregon coast, Gods country
    Posts
    755

    Default

    Foud this morning at Chuck Hawks site,, interesting read
    M4, M16 and 5.65mm NATO cartridge: A Disgrace?

Page 2 of 2 FirstFirst 12

Tags for this Thread

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •